☆ INTRODUCTION
IR60TR1A radar module is a radar module that uses 60G millimeter wave radar technology to realize the functions of moving human body perception, position detection and track tracking. This module is based on FMCW radar system to realize wireless perception of personnel status in specific places. It can be tested with our radar test board.(DERADAR-24G), or our converter adapter module(iflabel Link)
Relevant manual about this product on Library
☆ FEATURE
● Realize the function of position detection and track tracking of moving personnel;
● Limit the detection object to people with biological characteristics (moving or stationary), and eliminate the interference of other inanimate objects in the environment;
● This module can effectively eliminate the interference of non living objects, and can also realize the detection of non living moving objects;
● The product supports secondary development and adapts to a variety of scenarios;
● General UART communication interface, providing general protocol;
● Four groups of I \ O are reserved, which can be input and output according to user-defined or simple interface simulation;
● The output power is small and does no harm to human body;
● The module is not affected by temperature, light, dust and other factors, with high sensitivity and wide application fields.
☆ THE ABOVE PRICE INCLUDE
1) Wireless 60G Radar Module for Human Movement Tracking * 1pc
☆ OPERATING MODE
The beam coverage of radar module is shown in. The radar coverage is a three-dimensional sector area with 100 ° horizontal and 100 ° pitch.

Due to the influence of radar beam characteristics, the radar operates far in the normal direction of the antenna surface, but the operating distance deviates from the normal direction of the antenna will become shorter.
☆ INSTALLATION METHOD
There commended installation method of this radar module is horizontal installation.
Horizontal-mounted
The radar is installed horizontally (as shown in the Figure), and the radar is fixed on the wall or placed on the desktop, and the radar beam irradiates the human body in a positive direction.

.
☆ MAIN FUNCTION
1. MainFunctions
1) Moving target detection;
2) Slight motion target detection;
3) Statistics function for counting people number;
2. Main Parameters for Performance
1) Max Detection Range: ≤12m;(moving objects, limited to adults)
2) Stationary Detection Range:≤8m;(sitting, radial direction)
3) Ranging Accuracy:≤0.5m;
4) Angle Measurement Accuracy:≤5°;(object ≥2m)
5) Refresh Rate for Motion Detection:≥10Hz;
6) Response Time for Stationary Detection:≤30s;
7) Maximum of Counting Personnel Number:10;
8) Maximum of Tracking of Personnel:3;
☆ ABOUT US
Please feel free to contact us for any questions, on trademanager, or send message to me. It's our pleasure to serve you! We appreciate your business!!
My email is: info@good-display.com

☆ SPECIFICATION
1) 60G Radar Module for Human Perception And Track Tracking IR60TR1A
☆ ELECTRICAL PARAMETERS
1. Detection Angle and Distance
Parameters
|
Min |
Typ |
Max |
Unit |
Detection Range of Moving Personnel |
- |
12 |
- |
m |
Perception Distance of Static/ Slight-moving Personnel |
- |
6 |
- |
m |
Radar Detection Angle (Horizontal) |
- |
100 |
- |
° |
Radar Detection Angle(Pitch) |
- |
100 |
- |
° |
2. Electrical Characteristics
Operating Parameters |
Min |
Typ |
Max |
Unit |
Operating Voltage(VCC) |
4.5 |
5.0 |
6 |
V |
Operating Current(ICC) |
90 |
93 |
100 |
mA |
Operating Temperature(TOP) |
-20 |
- |
+60 |
℃ |
Storage Temperature(TST) |
-40 |
- |
+80 |
℃ |
3. RF Performance
Transmit Parameters |
Min |
Typ |
Max |
Unit |
Operating Frequency(fTX) |
58 |
- |
63.5 |
GHz |
Transmitting Power(Pout) |
- |
- |
6 |
dBm |
☆ EXTERNAL DIMENSION AND I/O PIN ASSIGNMENT
1. Outline Dimension

2. Pin Definition
Interface
|
Pin
|
Description
|
Typical
|
Remark
|
Interface 1
|
1
|
5V
|
5.0V
|
Positive end of power input
|
2 |
GDN |
|
Ground |
3 |
RX |
|
Serial port receive |
4 |
TX |
|
Serial port send |
5 |
S1 |
3.3V/0V |
|
6 |
S2 |
3.3V/0V |
|
Interface 2 |
1 |
3V3 |
3.3V |
Output power supply |
2 |
GND |
|
Ground |
3 |
SL |
|
Reserve |
4 |
SD |
|
Reserve |
5 |
GP1 |
|
Spare extension pin |
6 |
GP2 |
|
Spare extension pin |
7 |
GP3 |
|
Spare extension pin |
8 |
GP4 |
|
Spare extension pin |
24GHZ mmWave Radar Module (Serial Communication/ No access to Internet/ Secondary development)
|

|
Product Name
|
Radar Sensor for Human Presence Detection
|
Part Number
|
IR24VDA
|
Operating Frequency
|
24GHZ
|
Operating
Voltage/Current
|
5V/93mA
|
Dimension
|
35x30mm
|
Installation
|
Top/Inclined/Horizontal
|
Communication
|
Serial Communication
|
Main Functions
|
1. Some body state/Nobody state
2. Stationary/Active state
3. Output motion sign parmater
|
|

CLICK TO LEARN MORE
|
Product Name
|
Radar Sensor for Falling Detection
|
Part Number
|
IR24FDA
|
Operating Frequency
|
24GHZ
|
Operating
Voltage/Current
|
5V/93mA
|
Dimension
|
35x30mm
|
Installation
|
Top
|
Communication
|
Serial Communication
|
Main Functions
|
1. Some body state/Nobody state
2. Stationary/Active state
3. Output motion sign parmater
4. Falling Detection
|
|

CLICK TO LEARN MORE
|
Product Name
|
Radar Sensor for Vitial Sign and Sleeping Monitoring
|
Part Number
|
IR24BDA
|
Operating Frequency
|
24GHZ
|
Operating
Voltage/Current
|
5V/93mA
|
Dimension
|
46x27.5mm
|
Installation
|
Top/Inclined
|
Communication
|
Serial Communication
|
Main Functions
|
1. Some body state/Nobody state
2. Stationary/Active state
3. Output motion sign parmater
4. In bed/Out of bed state/ times
5. Sleep quality assessment
6. Breathing monitoring
|
24GHZ mmWave Radar Evaluation Board (Serial Communication/ Access to Internet/ Output Data on APP)
|
|
Product Name
|
24G mmWave Radar Evaluation Board
|
Part Number
|
DERADAR-24
|
Input Voltage/Current
|
DC5V ≥500mA
|
Dimension
|
70*55mA
|
Communication
|
Serial Communication, Tuya Cloud
|
Software
|
Tuya Smart APP
|
Main Functions
|
1. For connecting 24G radar : IR24VDA, IR24FDA, IR24BDA
2. Access to Tuya Cloud
3. Cloud to Cloud connection
4. Output data on APP
|
Product reviews can be carried out after the member login, please